- 4 different
water treatment recipes (different fertilizer combinations):
Every valve group can be irrigated with a different recipe.
- Dosing
according to EC and pH value, or proportionately
- Control
of up to 6 dosing channels for fertilizer (EC control) and
acid or lye (pH control)
- Flow
measurement for accurate dosing, and for alarm in case of
failure
- Central
drainage measurement
- Control
of 60 irrigation valves
- Sequencer
for operation of up to 10 outputs in a sequence, according
to certain measurements (e.g. for operation of misting valves
for cooling)
- Three
universal measurements 0-5 V or 0-20mA for general measurements
that can be used, for example, for a locally purchased,
electronic, humidity sensor
- The
combination of the last two features can be used as a basic
control of misting valves for cooling and humidification
Note!
The sequencer does not control the humidity and/or the temperature.
It starts working above a given measurement value, and stops
below another given value.
|
|