:: GREENHOUSES DIVISION  
   
  PCJ and PCJ – CNL Drippers  
     
 
  • Compact Pressure compensated dripper with or without anti-drain feature.
 

Applications

 
 
  • Greenhouses, nurseries, citrus, orchards, deciduous and trees irrigation.
 
  Specifications  
 
  • Working pressure in the PCJ model - 0.5 to 4.0 bar
  • Working pressure in the PCJ - CNL model - 0.7 to 4.0 bar
  • Turbonet" labyrinth with large water passages.
  • 5 different flow rates
  • 3 different outlets: nipple, barb to 3 mm ID and barb to 4 mm ID
  • To be “inserted" into thick- walled pipes (0.9, 1.0 and 1.2 mm.)
  • Injected dripper, very low CV.
 
  Features and Benefits  
 
  • PC system, patented pressure differential system maintains uniform flow rate at different inlet working pressure (in the recommended working pressure range), ensuring exact distribution of the water and fertilizers.
  • Self-flushing system, improves resistance to clogging.
  • In the PCJ – CNL model, anti-drain (CNL) system eliminates drainage and refill effect, thus improving efficiency in pulse irrigation.
  • Dripper can be positioned exactly where required.
  • Number of drippers can be increased so as to increase water quantity supply aimed at meeting tree growth rate requirement.
  • Allows the installation of "spider assembly", splitting the drip supply to a number of drip outlets
 
  Dripper technical data  
  PCJ model  
 

Nominal
Flow rate (l/h.)

Pressure range (bar)

Water passages dimensions
Width-depth-length (mm.)

 Cons-tant
K

Expo*
X

Base code
Color

Cap code color

1.2

0.5-4.0

0.67 x 0.77 x35

1.2

0

 Brown

Black

2.0

0.5-4.0

1.03 x 0.85 x 25

2.0

0

Red

Black

3.0

0.5-4.0

1.03 x 1.10 x 25

3.0

0

Blue

Black

4.0

0.5-4.0

1.20 x 1.05 x 25

4.0

0

Gray

Black

8.0

0.5-4.0

1.90 x 1.15 x 25

8.0

0

Green

Black

 
  Within the working pressure range  
   
  PCJ-CNL model (distinguishable from the PCJ model by rings around the bottom of the dripper)
 
 

Nominal
Flow rate (l/h.)

Pressure range (bar)

Water passages dimensions
Width-depth-length (mm.)

 Constant
K

Exp*
X

 Shut-off Pressure (bar) 

Base code
Color

Cap code color

1.2

 0.7-4.0

0.67x0.7x35

1.2

0.12 

 Brown

Black

2.0

0.5-4.0

1.03x0.85x25

2.0

0

0.12 

Red

Black

3.0

0.5-4.0

1.03x1.10x25

3.0

0

0.12 

Blue

Black

4.0

0.5-4.0

1.20x1.05x25

4.0

0

0.12 

Gray

Black

8.0

0.5-4.0

1.90x1.15x25

8.0

0

0.12 

Green

Black

 
  Within the working pressure range  
   
 
  • When inserting drippers in tubes with 0.9 mm wall thickness, the maximal working pressure recommended is 3 Bar.
  • When inserting drippers in tubes with 1.0 mm wall thickness, the maximal working pressure recommended is 3.5 Bar.
  • When inserting drippers in tubes with 1.2 mm wall thickness, the maximal working pressure recommended is 4 Bar.
 
  Technical Specifications:  
  PCJ & PCJ-CNL